ED-363AG4-C27 C
58.15 kW
Defrost: None
Product code: ED-450AG7-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 26,429 m³/h |
|---|---|
| Air throw | 21 m |
| External surface | 228.9 m² |
| Inner volume | 78.9 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 344 kg |
| Quantity | 4 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,300 rpm |
| Power | 2,720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 84.1 dB(A) |
| Energy class | C |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| ED-450AG7-C21 C | None |
|---|---|
| ED-450AG7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 23.55 | 24.67 | 25.66 | 26.48 | 26.94 | 27.11 | 27.03 | 27.51 | 29.26 | 31.73 | 30.93 | 30.66 | 30.28 | 29.73 |
| 5 | 28.97 | 30.83 | 32.51 | 33.95 | 34.88 | 35.37 | 35.43 | 35.99 | 38.25 | 41.51 | 40.34 | 39.92 | 39.29 | 38.28 |
| 6 | 33.53 | 36.10 | 38.47 | 40.21 | 41.72 | 42.69 | 43.21 | 44.00 | 46.82 | 50.96 | 49.84 | 49.39 | 48.69 | 47.43 |
| 7 | 37.47 | 40.84 | 43.58 | 46.34 | 48.38 | 49.79 | 50.59 | 51.58 | 54.90 | 59.78 | 58.57 | 58.02 | 57.16 | 55.66 |
| 8 | ≈ 40.97 | 44.74 | 48.62 | 52.14 | 54.84 | 56.71 | 57.90 | 59.14 | 62.98 | 68.61 | 67.33 | 66.71 | 65.71 | 63.93 |
| 9 | ≈ 36.40 | ≈ 48.60 | 53.31 | 57.65 | 61.01 | 63.47 | 65.10 | 66.65 | 71.03 | 77.42 | 76.12 | 75.43 | 74.33 | 72.30 |
| 10 | ≈ 21.79 | ≈ 52.10 | 57.66 | 62.81 | 66.95 | 70.06 | 72.17 | 74.09 | 79.02 | 86.20 | 84.91 | 84.18 | 82.98 | 80.73 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 84.908 |
| SC2 | 0 | 8 | 59.141 |
| SC3 | -18 | 7 | 47.238 |
| SC4 | -25 | 6 | 38.465 |
| SC5 | -34 | 6 | 34.113 |
| A | 4368 mm |
|---|---|
| B | 1350 mm |
| C | 405 mm |
| F | 1135 mm |
| G | 506 mm |
| E1 | 4035 mm |
| E2 | 1018 mm |
| E3 | 1000 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4368 mm |
|---|---|
| Width | 1350 mm |
| Height | 506 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.