EG-330AE7-C21 C
6.90 kW
Defrost: Electric
Product code: EG-235BC4-C21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,517 m³/h |
|---|---|
| Air throw | 16 m |
| External surface | 22.8 m² |
| Inner volume | 3.8 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 37 kg |
| Quantity | 2 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 330 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 73.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø19 |
| EG-235BC4-C21 C | None |
|---|---|
| EG-235BC4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.83 | 2.92 | 3.00 | 3.06 | 3.09 | 3.08 | 3.04 | 3.11 | 3.31 | 3.58 | 3.49 | 3.46 | 3.41 | 3.33 |
| 5 | 3.48 | 3.65 | 3.79 | 3.92 | 4.00 | 4.04 | 4.05 | 4.13 | 4.40 | 4.78 | 4.67 | 4.64 | 4.59 | 4.51 |
| 6 | 4.11 | 4.35 | 4.57 | 4.75 | 4.88 | 4.94 | 4.96 | 5.05 | 5.37 | 5.84 | 5.70 | 5.65 | 5.58 | 5.46 |
| 7 | 4.65 | 4.98 | 5.29 | 5.56 | 5.74 | 5.85 | 5.90 | 5.98 | 6.35 | 6.91 | 6.75 | 6.69 | 6.59 | 6.43 |
| 8 | ≈ 5.13 | 5.57 | 5.98 | 6.28 | 6.54 | 6.71 | 6.80 | 6.92 | 7.36 | 8.01 | 7.83 | 7.75 | 7.63 | 7.44 |
| 9 | ≈ 5.57 | 6.12 | 6.57 | 7.02 | 7.35 | 7.58 | 7.71 | 7.86 | 8.37 | 9.11 | 8.92 | 8.83 | 8.70 | 8.47 |
| 10 | ≈ 5.96 | 6.62 | 7.17 | 7.72 | 8.13 | 8.43 | 8.62 | 8.81 | 9.38 | 10.22 | 10.02 | 9.93 | 9.78 | 9.51 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 10.024 |
| SC2 | 0 | 8 | 6.919 |
| SC3 | -18 | 7 | 5.639 |
| SC4 | -25 | 6 | 4.565 |
| SC5 | -34 | 6 | 4.161 |
| A | 2097 mm |
|---|---|
| B | 685 mm |
| C | 310 mm |
| F | 630 mm |
| E1 | 893 mm |
| E | 1785 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø19 |
| Length | 2097 mm |
|---|---|
| Width | 685 mm |
| Height | 310 mm |