EG-335CE4-C21 C
11.70 kW
Defrost: Electric
Product code: EG-335CG7-C21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,382 m³/h |
|---|---|
| Air throw | 17 m |
| External surface | 39.1 m² |
| Inner volume | 10.7 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 63 kg |
| Quantity | 3 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 495 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø28 |
| EG-335CG7-C21 C | None |
|---|---|
| EG-335CG7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.15 | 5.25 | 5.34 | 5.42 | 5.44 | 5.40 | 5.32 | 5.47 | 5.83 | 6.32 | 6.15 | 6.10 | 6.04 | 5.95 |
| 5 | 6.43 | 6.65 | 6.86 | 7.02 | 7.10 | 7.10 | 7.03 | 7.15 | 7.59 | 8.23 | 7.95 | 7.85 | 7.69 | 7.45 |
| 6 | 7.60 | 7.94 | 8.26 | 8.54 | 8.71 | 8.79 | 8.77 | 8.90 | 9.44 | 10.23 | 9.87 | 9.72 | 9.50 | 9.14 |
| 7 | 8.62 | 9.11 | 9.56 | 9.95 | 10.20 | 10.33 | 10.33 | 10.49 | 11.13 | 12.07 | 11.70 | 11.54 | 11.30 | 10.88 |
| 8 | 9.67 | 10.29 | 10.87 | 11.37 | 11.70 | 11.85 | 11.90 | 12.07 | 12.81 | 13.87 | 13.46 | 13.27 | 12.97 | 12.46 |
| 9 | 10.55 | 11.34 | 12.08 | 12.72 | 13.15 | 13.40 | 13.48 | 13.67 | 14.49 | 15.69 | 15.24 | 15.02 | 14.67 | 14.06 |
| 10 | 11.35 | 12.32 | 13.23 | 14.01 | 14.57 | 14.91 | 14.98 | 15.23 | 16.16 | 17.49 | 17.00 | 16.76 | 16.37 | 15.69 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 17.000 |
| SC2 | 0 | 8 | 12.074 |
| SC3 | -18 | 7 | 10.069 |
| SC4 | -25 | 6 | 8.262 |
| SC5 | -34 | 6 | 7.677 |
| A | 2447 mm |
|---|---|
| B | 740 mm |
| C | 370 mm |
| F | 685 mm |
| E1 | 718 mm |
| E2 | 700 mm |
| E | 2135 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø28 |
| Length | 2447 mm |
|---|---|
| Width | 740 mm |
| Height | 370 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.