EG-235CG4-C21 C
8.92 kW
Defrost: None
Product code: EG-430AE4-C25 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 3,611 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 47.2 m² |
| Inner volume | 8.0 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 65 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 46.0 dB(A) |
|---|---|
| Sound power | 68.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø22 |
| EG-430AE4-C25 C | None |
|---|---|
| EG-430AE4-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.37 | 3.65 | 3.91 | 4.13 | 4.28 | 4.38 | 4.42 | 4.56 | 4.87 | 5.31 | 5.20 | 5.16 | 5.10 | 5.01 |
| 5 | ≈ 3.98 | 4.37 | 4.73 | 5.05 | 5.28 | 5.44 | 5.51 | 5.66 | 6.04 | 6.59 | 6.46 | 6.40 | 6.31 | 6.16 |
| 6 | ≈ 4.58 | 5.07 | 5.54 | 5.96 | 6.28 | 6.50 | 6.61 | 6.78 | 7.19 | 7.85 | 7.69 | 7.62 | 7.50 | 7.29 |
| 7 | ≈ 4.39 | ≈ 5.66 | 6.26 | 6.80 | 7.23 | 7.45 | 7.64 | 7.85 | 8.37 | 9.13 | 8.95 | 8.86 | 8.72 | 8.46 |
| 8 | not rated | ≈ 6.19 | 6.92 | 7.44 | 8.03 | 8.42 | 8.67 | 8.93 | 9.53 | 10.40 | 10.22 | 10.12 | 9.96 | 9.65 |
| 9 | not rated | ≈ 5.99 | ≈ 7.52 | 8.21 | 8.85 | 9.34 | 9.68 | 10.00 | 10.67 | 11.66 | 11.49 | 11.38 | 11.20 | 10.85 |
| 10 | not rated | not rated | ≈ 7.52 | ≈ 8.87 | 9.63 | 10.23 | 10.66 | 11.04 | 11.80 | 12.91 | 12.75 | 12.63 | 12.44 | 12.06 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 12.746 |
| SC2 | 0 | 8 | 8.929 |
| SC3 | -18 | 7 | 6.988 |
| SC4 | -25 | 6 | 5.539 |
| SC5 | -34 | 6 | 4.683 |
| A | 3546 mm |
|---|---|
| B | 685 mm |
| C | 245 mm |
| F | 630 mm |
| E1 | 818 mm |
| E2 | 800 mm |
| E | 3235 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø22 |
| Length | 3546 mm |
|---|---|
| Width | 685 mm |
| Height | 245 mm |
Our engineers answer with a selection for your conditions.