EG-430AE7-C21 C
9.09 kW
Defrost: Electric
Product code: EG-430BE7-C21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 4,631 m³/h |
|---|---|
| Air throw | 15 m |
| External surface | 29.8 m² |
| Inner volume | 8.2 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 62 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 248 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 49.0 dB(A) |
|---|---|
| Sound power | 71.3 dB(A) |
| Energy class | B |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EG-430BE7-C21 C | None |
|---|---|
| EG-430BE7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.88 | 3.91 | 3.94 | 3.97 | 3.96 | 3.94 | 3.89 | 3.96 | 4.21 | 4.55 | 4.43 | 4.40 | 4.34 | 4.27 |
| 5 | 4.91 | 5.01 | 5.11 | 5.20 | 5.23 | 5.22 | 5.17 | 5.23 | 5.55 | 6.01 | 5.82 | 5.76 | 5.66 | 5.51 |
| 6 | 5.89 | 6.08 | 6.27 | 6.43 | 6.52 | 6.54 | 6.51 | 6.57 | 6.97 | 7.54 | 7.31 | 7.22 | 7.08 | 6.85 |
| 7 | 6.75 | 7.03 | 7.30 | 7.54 | 7.70 | 7.79 | 7.81 | 7.91 | 8.39 | 9.11 | 8.86 | 8.74 | 8.57 | 8.28 |
| 8 | 7.60 | 7.98 | 8.33 | 8.63 | 8.84 | 8.96 | 9.01 | 9.13 | 9.69 | 10.51 | 10.25 | 10.13 | 9.95 | 9.64 |
| 9 | 8.35 | 8.85 | 9.31 | 9.72 | 9.99 | 10.14 | 10.22 | 10.36 | 11.00 | 11.92 | 11.64 | 11.50 | 11.30 | 10.91 |
| 10 | 9.03 | 9.66 | 10.24 | 10.74 | 11.10 | 11.33 | 11.44 | 11.59 | 12.31 | 13.35 | 13.02 | 12.87 | 12.64 | 12.20 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 13.022 |
| SC2 | 0 | 8 | 9.127 |
| SC3 | -18 | 7 | 7.616 |
| SC4 | -25 | 6 | 6.269 |
| SC5 | -34 | 6 | 5.937 |
| A | 2266 mm |
|---|---|
| B | 685 mm |
| C | 370 mm |
| F | 630 mm |
| E1 | 498 mm |
| E2 | 480 mm |
| E | 1955 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 2266 mm |
|---|---|
| Width | 685 mm |
| Height | 370 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.