Dry cooler BC/BD-380AB5-B01 C

Dry cooler BC/BD-380AB5-B01 C
Illustrative photo

Producer: Karyer · Line: BC/BD (General)

Product code: BC/BD-380AB5-B01 C

Heat rejection i
126.62 kW
Air flow
54,130 m³/h
Fans
3 × ⌀800 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: BC/BD — BC = vertical, BD = horizontal dry cooler (air flow bottom to top).
  • D
    Number of fans per row: 3 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 80 — Ø800 mm
  • G
    Coil tube rows (2nd dimensional letter): B — 3 tube rows
  • H
    Fin spacing: 5 — 2.5 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 01 — fan motor code; supply/poles vary with diameter

Data

Coil
Air flow 54,130 m³/h
External surface 313.4 m²
Inner volume 48.3 dm³
Fin materialAluminium
Net weight 493 kg
Fans
Quantity 3
Diameter 800 mm
Speed 900 rpm
Power 5,400 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 54.0 dB(A)
Sound power 86.0 dB(A)
Energy class E
Connections
Inlet 2 1/2"
Outlet 2 1/2"
Defrost
BC/BD-380AB5-B01 C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
126.619 kW Fluid flow 21.97 m³/h Pressure drop 49.7 kPa
Heat rejection · Low speed (Y)
103.240 kW Fluid flow 17.92 m³/h Pressure drop 34.6 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 71.34 not rated not rated not rated not rated not rated
40 126.62 71.89 not rated not rated not rated not rated
45 180.88 126.97 72.39 not rated not rated not rated
50 234.81 181.05 127.30 72.84 not rated not rated
55 288.61 234.82 181.25 127.65 73.29 not rated
60 342.31 288.46 234.89 181.51 128.04 73.74

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 58.60 not rated not rated not rated not rated not rated
40 103.24 59.01 not rated not rated not rated not rated
45 146.93 103.44 59.38 not rated not rated not rated
50 190.33 146.95 103.64 59.72 not rated not rated
55 233.58 190.18 147.01 103.86 60.06 not rated
60 276.75 233.27 190.10 147.13 104.13 60.42

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 126.619 21.97 49.7
Low speed (Y) 103.240 17.92 34.6

Dimensions

Dimension drawing of BC/BD-380AB5-B01 C
Dimension drawing
Dimensions as drawn
A 3950 mm
B 1450 mm
C 1240 mm
F 1150 mm
G 550 mm
E 3700 mm
H 1200 mm
I 1190 mm
K 4250 mm
D IN 2 1/2"
D OUT 2 1/2"
Overall [mm]
Length 3950 mm
Width 1240 mm
Height 1450 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.