Dry cooler BE-2x280CB5-B01C C

Dry cooler BE-2x280CB5-B01C C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-2x280CB5-B01C C

Heat rejection i
307.02 kW
Air flow
89,592 m³/h
Fans
4 × ⌀800 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: BE — BE = V-type dry cooler.
  • C
    Fan rows (optional "Nx"): 2 — Catalogue: "Fan Row no." (number before x/X).
  • D
    Number of fans per row: 2 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 80 — Ø800 mm
  • G
    Coil tube rows (2nd dimensional letter): B — 3 tube rows
  • H
    Fin spacing: 5 — 2.5 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 01 — three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
  • K
    Delivery version (optional): C — C: container delivery version

Data

Coil
Air flow 89,592 m³/h
External surface 1,461.3 m²
Inner volume 211.0 dm³
Fin materialAluminium
Net weight 1,636 kg
Fans
Quantity 4
Diameter 800 mm
Speed 900 rpm
Power 7,200 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 54.0 dB(A)
Sound power 86.1 dB(A)
Energy class D
Connections
Inlet 2 1/2"
Outlet 2 1/2"
Defrost
BE-2x280CB5-B01C C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
307.019 kW Fluid flow 53.28 m³/h Pressure drop 79.4 kPa above the recommended pressure drop
Heat rejection · Low speed (Y)
243.962 kW Fluid flow 42.34 m³/h Pressure drop 52.8 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 182.38 not rated not rated not rated not rated not rated
40 307.02 182.20 not rated not rated not rated not rated
45 428.74 305.82 182.02 not rated not rated not rated
50 549.49 426.59 304.77 181.89 not rated not rated
55 669.78 546.41 424.71 303.89 181.85 not rated
60 789.85 665.82 543.71 423.11 303.28 181.95

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 146.10 not rated not rated not rated not rated not rated
40 243.96 145.86 not rated not rated not rated not rated
45 339.31 242.82 145.65 not rated not rated not rated
50 433.86 337.38 241.83 145.47 not rated not rated
55 528.03 431.15 335.68 241.02 145.39 not rated
60 622.00 524.55 428.76 334.29 240.44 145.45

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 307.019 53.28 79.4
Low speed (Y) 243.962 42.34 52.8

Dimensions

Dimension drawing of BE-2x280CB5-B01C C
Dimension drawing
Dimensions as drawn
A 2453 mm
B 2300 mm
C 5250 mm
F 2230 mm
G 5850 mm
E1 2450 mm
H 5500 mm
D IN 2 1/2"
D OUT 2 1/2"
Overall [mm]
Length 5850 mm
Width 2300 mm
Height 2453 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.