BE-2x880AD1-B01C C
1242.95 kW
Defrost: None
Product code: BE-2x891EB1-C04C C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
How to read the code of this model.
| Air flow | 412,261 m³/h |
|---|---|
| External surface | 3,146.7 m² |
| Inner volume | 647.2 dm³ |
| Fin material | Aluminium |
| Net weight | 4,343 kg |
| Quantity | 16 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 44,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 71.0 dB(A) |
|---|---|
| Sound power | 103.6 dB(A) |
| Energy class | E |
| Inlet | 5" |
|---|---|
| Outlet | 5" |
| BE-2x891EB1-C04C C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 725.18 | not rated | not rated | not rated | not rated | not rated |
| 40 | 1247.35 | 727.36 | not rated | not rated | not rated | not rated |
| 45 | 1758.39 | 1246.63 | 729.26 | not rated | not rated | not rated |
| 50 | 2265.82 | 1755.05 | 1246.25 | 731.17 | not rated | not rated |
| 55 | 2771.50 | 2259.93 | 1752.48 | 1246.34 | 733.29 | not rated |
| 60 | 3276.29 | 2763.20 | 2255.19 | 1750.89 | 1247.28 | 735.85 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 579.07 | not rated | not rated | not rated | not rated | not rated |
| 40 | 987.13 | 580.75 | not rated | not rated | not rated | not rated |
| 45 | 1385.58 | 986.49 | 582.26 | not rated | not rated | not rated |
| 50 | 1780.81 | 1382.80 | 986.13 | 583.85 | not rated | not rated |
| 55 | 2174.55 | 1776.04 | 1380.77 | 986.32 | 585.69 | not rated |
| 60 | 2567.34 | 2167.71 | 1772.23 | 1379.71 | 987.37 | 588.04 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 1247.345 | 216.47 | 98.0 |
| Low speed (Y) | 987.129 | 171.31 | 64.7 |
| A | 2511 mm |
|---|---|
| B | 2300 mm |
| C | 10050 mm |
| F | 2230 mm |
| G | 10650 mm |
| E1 | 1250 mm |
| E2 | 2400 mm |
| H | 10300 mm |
| D IN | 5" |
| D OUT | 5" |
| Length | 10050 mm |
|---|---|
| Width | 2300 mm |
| Height | 2511 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.