BE-2X580BC5-B01T C
655.26 kW
Defrost: None
Product code: BE-880EC1-B01 C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Air flow | 164,746 m³/h |
|---|---|
| External surface | 2,859.4 m² |
| Inner volume | 546.5 dm³ |
| Fin material | Aluminium |
| Net weight | 2,464 kg |
| Quantity | 8 |
|---|---|
| Diameter | 800 mm |
| Speed | 900 rpm |
| Power | 14,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 89.0 dB(A) |
| Energy class | D |
| Inlet | 4" |
|---|---|
| Outlet | 4" |
| BE-880EC1-B01 C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 391.90 | not rated | not rated | not rated | not rated | not rated |
| 40 | 653.88 | 391.78 | not rated | not rated | not rated | not rated |
| 45 | 908.29 | 651.32 | 391.67 | not rated | not rated | not rated |
| 50 | 1160.15 | 903.54 | 649.11 | 391.58 | not rated | not rated |
| 55 | 1410.80 | 1153.29 | 899.45 | 647.44 | 391.89 | not rated |
| 60 | 1660.80 | 1401.89 | 1147.41 | 896.27 | 646.48 | 392.57 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 303.33 | not rated | not rated | not rated | not rated | not rated |
| 40 | 500.83 | 303.15 | not rated | not rated | not rated | not rated |
| 45 | 692.13 | 498.69 | 302.99 | not rated | not rated | not rated |
| 50 | 881.34 | 688.28 | 496.90 | 302.96 | not rated | not rated |
| 55 | 1069.58 | 875.87 | 685.02 | 495.55 | 303.19 | not rated |
| 60 | 1257.29 | 1062.53 | 871.23 | 682.53 | 494.84 | 303.79 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 653.882 | 113.41 | 38.3 |
| Low speed (Y) | 500.834 | 86.85 | 23.8 |
| A | 1808 mm |
|---|---|
| B | 1300 mm |
| C | 10060 mm |
| F | 1150 mm |
| G | 10660 mm |
| E1 | 1230 mm |
| E2 | 1200 mm |
| D IN | 4" |
| D OUT | 4" |
| Length | 10660 mm |
|---|---|
| Width | 1300 mm |
| Height | 1808 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.