- Catalogue
- Dry coolers
- BE (Dry)
BE (Dry)
- Refrigerants
- ETHYLENE GLYCOL 30%, PROPYLENE GLYCOL 30%, WATER
- Capacity
- 69.30–1727.54 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 10 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series BE = BE = V-type dry cooler.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| BE-t-2x180HC5-B01T C | 185.83 kW | 2 × ⌀800 | 43,581 |
Variants (1) |
| BE-291BD5-B04 C | 186.32 kW | 2 × ⌀910 | 54,350 |
Variants (1)
|
| BE-2x180CD5-B01C C | 186.63 kW | 2 × ⌀800 | 43,897 |
Variants (1) |
| BE-t-2x191HB5-C04C C | 187.29 kW | 2 × ⌀910 | 56,932 |
Variants (1) |
| BE-t-2x180HC1-B01C C | 187.48 kW | 2 × ⌀800 | 42,444 |
Variants (1) |
| BE-2x180CC1-B01T C | 189.27 kW | 2 × ⌀800 | 44,589 |
Variants (1) |
| BE-2x191DC5-B04T C | 190.97 kW | 2 × ⌀910 | 58,036 |
Variants (1) |
| BE-380BB1-B01 C | 191.30 kW | 3 × ⌀800 | 64,175 |
Variants (1)
|
| BE-2x191DC1-C04C C | 192.15 kW | 2 × ⌀910 | 56,048 |
Variants (1) |
| BE-t-280HC5-B01 C | 192.57 kW | 2 × ⌀800 | 43,920 |
Variants (1)
|
| BE-2x180CD5-B01T C | 192.86 kW | 2 × ⌀800 | 44,399 |
Variants (1) |
| BE-t-291GB1-B04 C | 193.02 kW | 2 × ⌀910 | 55,407 |
Variants (1)
|
| BE-280CC1-B01 C | 193.65 kW | 2 × ⌀800 | 44,871 |
Variants (1)
|
| BE-2x180CD1-B01C C | 194.39 kW | 2 × ⌀800 | 43,649 |
Variants (1) |
| BE-291AC1-B04 C | 194.88 kW | 2 × ⌀910 | 54,801 |
Variants (1)
|
| BE-380AB5-B01 C | 196.27 kW | 3 × ⌀800 | 65,095 |
Variants (1)
|
| BE-t-2x180HC1-B01T C | 196.45 kW | 2 × ⌀800 | 43,306 |
Variants (1) |
| BE-291DC5-B04 C | 196.61 kW | 2 × ⌀910 | 58,551 |
Variants (1)
|
| BE-2x191CB5-B04T C | 197.89 kW | 2 × ⌀910 | 59,970 |
Variants (1) |
| BE-280CD5-B01 C | 197.91 kW | 2 × ⌀800 | 44,712 |
Variants (1)
|
| BE-291AD5-B04 C | 198.10 kW | 2 × ⌀910 | 54,121 |
Variants (1)
|
| BE-2x191CB1-C04C C | 198.65 kW | 2 × ⌀910 | 58,885 |
Variants (1) |
| BE-291BD1-B04 C | 198.84 kW | 2 × ⌀910 | 53,643 |
Variants (1)
|
| BE-2x180CD1-B01T C | 200.21 kW | 2 × ⌀800 | 44,200 |
Variants (1) |
| BE-t-2x191HB5-B04T C | 202.10 kW | 2 × ⌀910 | 58,298 |
Variants (1) |
| BE-t-280HC1-B01 C | 202.86 kW | 2 × ⌀800 | 43,676 |
Variants (1)
|
| BE-t-291GC5-B04 C | 203.22 kW | 2 × ⌀910 | 54,398 |
Variants (1)
|
| BE-t-2x191HB1-C04C C | 203.83 kW | 2 × ⌀910 | 56,418 |
Variants (1) |
| BE-280CD1-B01 C | 204.85 kW | 2 × ⌀800 | 44,545 |
Variants (1)
|
| BE-291CB5-B04 C | 205.15 kW | 2 × ⌀910 | 60,317 |
Variants (1)
|
| BE-380BC5-B01 C | 205.40 kW | 3 × ⌀800 | 63,228 |
Variants (1)
|
| BE-2x191DC1-B04T C | 205.95 kW | 2 × ⌀910 | 57,619 |
Variants (1) |
| BE-2x280BB5-B01C C | 206.37 kW | 4 × ⌀800 | 83,087 |
Variants (1) |
| BE-380DB5-B01 C | 207.72 kW | 3 × ⌀800 | 67,200 |
Variants (1)
|
| BE-t-291HB5-B04 C | 208.34 kW | 2 × ⌀910 | 58,782 |
Variants (1)
|
| BE-291AD1-B04 C | 209.56 kW | 2 × ⌀910 | 53,371 |
Variants (1)
|
| BE-291DC1-B04 C | 211.66 kW | 2 × ⌀910 | 58,181 |
Variants (1)
|
| BE-2x191CC5-C04C C | 211.69 kW | 2 × ⌀910 | 58,302 |
Variants (1) |
| BE-380AB1-B01 C | 213.71 kW | 3 × ⌀800 | 64,656 |
Variants (1)
|
| BE-t-380GB5-B01 C | 214.11 kW | 3 × ⌀800 | 63,646 |
Variants (1)
|
| BE-t-2x191HC5-C04C C | 214.16 kW | 2 × ⌀910 | 55,506 |
Variants (1) |
| BE-2x191CB1-B04T C | 214.19 kW | 2 × ⌀910 | 59,738 |
Variants (1) |
| BE-391BB5-B04 C | 217.14 kW | 3 × ⌀910 | 85,508 |
Variants (1)
|
| BE-t-291GC1-B04 C | 217.31 kW | 2 × ⌀910 | 53,699 |
Variants (1)
|
| BE-291DD5-B04 C | 218.21 kW | 2 × ⌀910 | 57,744 |
Variants (1)
|
| BE-t-2x191HB1-B04T C | 219.11 kW | 2 × ⌀910 | 57,904 |
Variants (1) |
| BE-380BC1-B01 C | 221.42 kW | 3 × ⌀800 | 62,564 |
Variants (1)
|
| BE-291CB1-B04 C | 221.43 kW | 2 × ⌀910 | 60,142 |
Variants (1)
|
| BE-2x280BB5-B01T C | 222.38 kW | 4 × ⌀800 | 85,322 |
Variants (1) |
| BE-2x191CC5-B04T C | 224.49 kW | 2 × ⌀910 | 59,298 |
Variants (1) |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
Downloads
- BE-t-2x180HC5-B01T C — product datasheet (PDF)
- BE-291BD5-B04 C — product datasheet (PDF)
- BE-2x180CD5-B01C C — product datasheet (PDF)
- BE-t-2x191HB5-C04C C — product datasheet (PDF)
- BE-t-2x180HC1-B01C C — product datasheet (PDF)
- BE-2x180CC1-B01T C — product datasheet (PDF)
- BE-2x191DC5-B04T C — product datasheet (PDF)
- BE-380BB1-B01 C — product datasheet (PDF)
- BE-2x191DC1-C04C C — product datasheet (PDF)
- BE-t-280HC5-B01 C — product datasheet (PDF)
- BE-2x180CD5-B01T C — product datasheet (PDF)
- BE-t-291GB1-B04 C — product datasheet (PDF)
- BE-280CC1-B01 C — product datasheet (PDF)
- BE-2x180CD1-B01C C — product datasheet (PDF)
- BE-291AC1-B04 C — product datasheet (PDF)
- BE-380AB5-B01 C — product datasheet (PDF)
- BE-t-2x180HC1-B01T C — product datasheet (PDF)
- BE-291DC5-B04 C — product datasheet (PDF)
- BE-2x191CB5-B04T C — product datasheet (PDF)
- BE-280CD5-B01 C — product datasheet (PDF)
- BE-291AD5-B04 C — product datasheet (PDF)
- BE-2x191CB1-C04C C — product datasheet (PDF)
- BE-291BD1-B04 C — product datasheet (PDF)
- BE-2x180CD1-B01T C — product datasheet (PDF)
- BE-t-2x191HB5-B04T C — product datasheet (PDF)
- BE-t-280HC1-B01 C — product datasheet (PDF)
- BE-t-291GC5-B04 C — product datasheet (PDF)
- BE-t-2x191HB1-C04C C — product datasheet (PDF)
- BE-280CD1-B01 C — product datasheet (PDF)
- BE-291CB5-B04 C — product datasheet (PDF)
- BE-380BC5-B01 C — product datasheet (PDF)
- BE-2x191DC1-B04T C — product datasheet (PDF)
- BE-2x280BB5-B01C C — product datasheet (PDF)
- BE-380DB5-B01 C — product datasheet (PDF)
- BE-t-291HB5-B04 C — product datasheet (PDF)
- BE-291AD1-B04 C — product datasheet (PDF)
- BE-291DC1-B04 C — product datasheet (PDF)
- BE-2x191CC5-C04C C — product datasheet (PDF)
- BE-380AB1-B01 C — product datasheet (PDF)
- BE-t-380GB5-B01 C — product datasheet (PDF)
- BE-t-2x191HC5-C04C C — product datasheet (PDF)
- BE-2x191CB1-B04T C — product datasheet (PDF)
- BE-391BB5-B04 C — product datasheet (PDF)
- BE-t-291GC1-B04 C — product datasheet (PDF)
- BE-291DD5-B04 C — product datasheet (PDF)
- BE-t-2x191HB1-B04T C — product datasheet (PDF)
- BE-380BC1-B01 C — product datasheet (PDF)
- BE-291CB1-B04 C — product datasheet (PDF)
- BE-2x280BB5-B01T C — product datasheet (PDF)
- BE-2x191CC5-B04T C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.