EA-130BC10-C05 C
1.89 kW
Defrost: Electric
Product code: EA-130AC7-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 1,314 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 6.7 m² |
| Inner volume | 2.3 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 22 kg |
| Quantity | 1 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 62 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 43.0 dB(A) |
|---|---|
| Sound power | 64.1 dB(A) |
| Energy class | B |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø12,7 |
| EA-130AC7-C01 C | None |
|---|---|
| EA-130AC7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 0.74 | 0.75 | 0.76 | 0.77 | 0.77 | 0.77 | 0.76 | 0.77 | 0.82 | 0.88 | 0.86 | 0.85 | 0.83 | 0.82 |
| 5 | 0.93 | 0.97 | 1.00 | 1.02 | 1.03 | 1.03 | 1.03 | 1.04 | 1.10 | 1.19 | 1.16 | 1.14 | 1.13 | 1.10 |
| 6 | 1.12 | 1.18 | 1.23 | 1.28 | 1.30 | 1.31 | 1.31 | 1.33 | 1.41 | 1.52 | 1.48 | 1.46 | 1.44 | 1.40 |
| 7 | 1.29 | 1.38 | 1.45 | 1.52 | 1.57 | 1.60 | 1.61 | 1.62 | 1.72 | 1.87 | 1.82 | 1.80 | 1.77 | 1.72 |
| 8 | 1.43 | 1.54 | 1.65 | 1.72 | 1.79 | 1.83 | 1.86 | 1.89 | 2.01 | 2.19 | 2.14 | 2.12 | 2.09 | 2.05 |
| 9 | ≈ 1.56 | 1.70 | 1.81 | 1.93 | 2.01 | 2.07 | 2.11 | 2.15 | 2.28 | 2.49 | 2.44 | 2.42 | 2.39 | 2.33 |
| 10 | ≈ 1.68 | 1.84 | 1.98 | 2.12 | 2.23 | 2.30 | 2.35 | 2.40 | 2.56 | 2.79 | 2.74 | 2.72 | 2.68 | 2.62 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 2.740 |
| SC2 | 0 | 8 | 1.888 |
| SC3 | -18 | 7 | 1.541 |
| SC4 | -25 | 6 | 1.234 |
| SC5 | -34 | 6 | 1.137 |
| A | 777 mm |
|---|---|
| B | 523 mm |
| C | 445 mm |
| F | 345 mm |
| E | 455 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø12,7 |
| Length | 777 mm |
|---|---|
| Width | 523 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.