EA-530AE6-C05 C
11.79 kW
Defrost: None
Product code: EA-163FC7-C19 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,124 m³/h |
|---|---|
| Air throw | 28 m |
| External surface | 56.3 m² |
| Inner volume | 17.2 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 112 kg |
| Quantity | 1 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 1,250 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 62.0 dB(A) |
|---|---|
| Sound power | 84.0 dB(A) |
| Energy class | E |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø28 |
| EA-163FC7-C19 C | None |
|---|---|
| EA-163FC7-C19 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.03 | 4.93 | 4.87 | 4.84 | 4.80 | 4.75 | 4.70 | 4.70 | 4.97 | 5.37 | 5.23 | 5.18 | 5.11 | 5.00 |
| 5 | 6.58 | 6.49 | 6.46 | 6.45 | 6.40 | 6.34 | 6.28 | 6.26 | 6.62 | 7.14 | 6.94 | 6.87 | 6.76 | 6.61 |
| 6 | 8.10 | 8.12 | 8.15 | 8.18 | 8.15 | 8.09 | 8.01 | 7.99 | 8.44 | 9.10 | 8.83 | 8.73 | 8.58 | 8.37 |
| 7 | 9.57 | 9.72 | 9.85 | 9.96 | 9.99 | 9.95 | 9.88 | 9.84 | 10.41 | 11.21 | 10.87 | 10.74 | 10.55 | 10.27 |
| 8 | 10.96 | 11.22 | 11.49 | 11.71 | 11.82 | 11.84 | 11.80 | 11.78 | 12.46 | 13.45 | 13.04 | 12.89 | 12.66 | 12.30 |
| 9 | 12.16 | 12.60 | 13.01 | 13.38 | 13.61 | 13.76 | 13.78 | 13.79 | 14.60 | 15.77 | 15.32 | 15.14 | 14.88 | 14.46 |
| 10 | 13.26 | 13.87 | 14.42 | 14.90 | 15.23 | 15.43 | 15.54 | 15.65 | 16.61 | 18.02 | 17.62 | 17.46 | 17.17 | 16.69 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.56 | 4.46 | 4.41 | 4.38 | 4.35 | 4.31 | 4.28 | 4.30 | 4.55 | 4.92 | 4.81 | 4.76 | 4.70 | 4.62 |
| 5 | 5.91 | 5.84 | 5.80 | 5.79 | 5.75 | 5.70 | 5.65 | 5.66 | 5.99 | 6.47 | 6.30 | 6.24 | 6.16 | 6.04 |
| 6 | 7.31 | 7.28 | 7.28 | 7.29 | 7.26 | 7.21 | 7.14 | 7.14 | 7.55 | 8.15 | 7.92 | 7.83 | 7.71 | 7.53 |
| 7 | 8.65 | 8.71 | 8.78 | 8.85 | 8.86 | 8.81 | 8.74 | 8.73 | 9.23 | 9.96 | 9.66 | 9.55 | 9.39 | 9.15 |
| 8 | 9.94 | 10.12 | 10.29 | 10.44 | 10.49 | 10.46 | 10.41 | 10.40 | 11.00 | 11.86 | 11.51 | 11.37 | 11.17 | 10.86 |
| 9 | 11.16 | 11.44 | 11.73 | 11.98 | 12.11 | 12.15 | 12.12 | 12.12 | 12.83 | 13.85 | 13.44 | 13.28 | 13.05 | 12.67 |
| 10 | 12.20 | 12.65 | 13.06 | 13.44 | 13.68 | 13.83 | 13.86 | 13.88 | 14.70 | 15.89 | 15.44 | 15.26 | 14.99 | 14.56 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 17.621 | 15.442 |
| SC2 | 0 | 8 | 11.783 | 10.396 |
| SC3 | -18 | 7 | 9.981 | 8.862 |
| SC4 | -25 | 6 | 8.149 | 7.280 |
| SC5 | -34 | 6 | 8.115 | 7.310 |
| A | 1415 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E | 1035 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø28 |
| Length | 1415 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.