EA-150AE7-C09 C
10.84 kW
Defrost: None
Product code: EA-240AC4-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,009 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 39.1 m² |
| Inner volume | 8.6 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 61 kg |
| Quantity | 2 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 320 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø35 |
| EA-240AC4-C01 C | None |
|---|---|
| EA-240AC4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.59 | 4.48 | 4.42 | 4.39 | 4.34 | 4.29 | 4.23 | 4.32 | 4.58 | 4.95 | 4.83 | 4.79 | 4.73 | 4.65 |
| 5 | 6.05 | 5.96 | 5.91 | 5.88 | 5.83 | 5.75 | 5.65 | 5.73 | 6.07 | 6.56 | 6.38 | 6.32 | 6.24 | 6.13 |
| 6 | 7.55 | 7.51 | 7.51 | 7.51 | 7.46 | 7.37 | 7.24 | 7.29 | 7.72 | 8.33 | 8.05 | 7.96 | 7.83 | 7.65 |
| 7 | 9.01 | 9.09 | 9.16 | 9.23 | 9.20 | 9.11 | 8.97 | 9.00 | 9.51 | 10.25 | 9.87 | 9.73 | 9.53 | 9.24 |
| 8 | 10.29 | 10.48 | 10.67 | 10.86 | 10.95 | 10.94 | 10.80 | 10.80 | 11.41 | 12.30 | 11.83 | 11.65 | 11.39 | 10.98 |
| 9 | 11.46 | 11.77 | 12.07 | 12.30 | 12.45 | 12.49 | 12.45 | 12.53 | 13.28 | 14.36 | 13.90 | 13.68 | 13.36 | 12.85 |
| 10 | 12.58 | 12.98 | 13.39 | 13.75 | 13.95 | 14.04 | 14.02 | 14.11 | 14.95 | 16.16 | 15.69 | 15.49 | 15.19 | 14.69 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 15.692 |
| SC2 | 0 | 8 | 10.800 |
| SC3 | -18 | 7 | 9.230 |
| SC4 | -25 | 6 | 7.509 |
| SC5 | -34 | 6 | 7.558 |
| A | 1467 mm |
|---|---|
| B | 586 mm |
| C | 605 mm |
| F | 395 mm |
| E1 | 568 mm |
| E | 1135 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø35 |
| Length | 1467 mm |
|---|---|
| Width | 586 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.