EA-163GD7-C19 C
18.59 kW
Defrost: None
Product code: EA-440AC6-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 12,725 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 56.1 m² |
| Inner volume | 16.1 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 104 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| EA-440AC6-C01 C | None |
|---|---|
| EA-440AC6-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.64 | 7.61 | 7.59 | 7.58 | 7.52 | 7.42 | 7.30 | 7.36 | 7.79 | 8.39 | 8.13 | 8.03 | 7.90 | 7.70 |
| 5 | 9.94 | 10.07 | 10.16 | 10.26 | 10.25 | 10.18 | 10.05 | 10.10 | 10.70 | 11.53 | 11.17 | 11.05 | 10.88 | 10.62 |
| 6 | 12.09 | 12.43 | 12.75 | 13.03 | 13.14 | 13.14 | 13.02 | 13.09 | 13.86 | 14.95 | 14.47 | 14.29 | 14.03 | 13.64 |
| 7 | 13.88 | 14.43 | 14.94 | 15.39 | 15.62 | 15.78 | 15.84 | 16.01 | 17.00 | 18.44 | 18.00 | 17.78 | 17.46 | 16.94 |
| 8 | 15.55 | 16.24 | 16.97 | 17.60 | 18.03 | 18.29 | 18.40 | 18.61 | 19.77 | 21.46 | 20.96 | 20.75 | 20.43 | 19.90 |
| 9 | 17.09 | 18.04 | 18.99 | 19.83 | 20.42 | 20.79 | 20.99 | 21.24 | 22.56 | 24.50 | 23.95 | 23.70 | 23.33 | 22.69 |
| 10 | 18.42 | 19.72 | 20.93 | 22.00 | 22.75 | 23.26 | 23.56 | 23.89 | 25.39 | 27.58 | 26.98 | 26.70 | 26.27 | 25.52 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 26.979 |
| SC2 | 0 | 8 | 18.611 |
| SC3 | -18 | 7 | 15.461 |
| SC4 | -25 | 6 | 12.754 |
| SC5 | -34 | 6 | 12.174 |
| A | 2567 mm |
|---|---|
| B | 586 mm |
| C | 605 mm |
| F | 395 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 2235 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2567 mm |
|---|---|
| Width | 586 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.