EA-245AG6-C01 C
20.36 kW
Defrost: None
Product code: EA-440AE8-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 11,722 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 64.9 m² |
| Inner volume | 23.7 dm³ |
| Fin spacing | 8.0 mm |
| Fin material | Aluminium |
| Net weight | 123 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø42 |
| EA-440AE8-C01 C | None |
|---|---|
| EA-440AE8-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 8.34 | 8.43 | 8.52 | 8.58 | 8.56 | 8.48 | 8.35 | 8.52 | 9.05 | 9.78 | 9.51 | 9.42 | 9.26 | 9.02 |
| 5 | 10.64 | 10.93 | 11.15 | 11.38 | 11.46 | 11.43 | 11.30 | 11.47 | 12.17 | 13.15 | 12.73 | 12.59 | 12.39 | 12.10 |
| 6 | 12.73 | 13.29 | 13.79 | 14.21 | 14.43 | 14.49 | 14.40 | 14.57 | 15.44 | 16.71 | 16.17 | 15.96 | 15.65 | 15.16 |
| 7 | 14.55 | 15.34 | 16.06 | 16.69 | 17.03 | 17.27 | 17.34 | 17.60 | 18.70 | 20.31 | 19.74 | 19.49 | 19.10 | 18.47 |
| 8 | 16.19 | 17.25 | 18.11 | 18.95 | 19.54 | 19.89 | 20.05 | 20.34 | 21.61 | 23.47 | 22.90 | 22.64 | 22.26 | 21.60 |
| 9 | 17.67 | 18.91 | 20.13 | 21.22 | 21.98 | 22.48 | 22.73 | 23.10 | 24.55 | 26.66 | 26.04 | 25.75 | 25.30 | 24.53 |
| 10 | ≈ 19.01 | 20.54 | 22.06 | 23.39 | 24.38 | 25.04 | 25.40 | 25.86 | 27.49 | 29.87 | 29.21 | 28.89 | 28.39 | 27.51 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 29.209 |
| SC2 | 0 | 8 | 20.343 |
| SC3 | -18 | 7 | 16.880 |
| SC4 | -25 | 6 | 13.789 |
| SC5 | -34 | 6 | 12.865 |
| A | 2567 mm |
|---|---|
| B | 636 mm |
| C | 605 mm |
| F | 445 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 2235 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø42 |
| Length | 2567 mm |
|---|---|
| Width | 636 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.