EA-430AC4-C01 C
10.10 kW
Defrost: Electric
Product code: EA-530AC7-C01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,498 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 32.6 m² |
| Inner volume | 11.0 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 69 kg |
| Quantity | 5 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 310 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 49.0 dB(A) |
|---|---|
| Sound power | 71.0 dB(A) |
| Energy class | B |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EA-530AC7-C01 C | None |
|---|---|
| EA-530AC7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.14 | 4.17 | 4.20 | 4.23 | 4.22 | 4.19 | 4.14 | 4.19 | 4.45 | 4.81 | 4.68 | 4.64 | 4.56 | 4.45 |
| 5 | 5.30 | 5.40 | 5.51 | 5.61 | 5.65 | 5.65 | 5.60 | 5.66 | 6.00 | 6.48 | 6.29 | 6.22 | 6.13 | 5.99 |
| 6 | 6.36 | 6.61 | 6.84 | 7.03 | 7.13 | 7.16 | 7.14 | 7.21 | 7.64 | 8.27 | 8.02 | 7.93 | 7.79 | 7.58 |
| 7 | 7.30 | 7.65 | 7.99 | 8.28 | 8.44 | 8.57 | 8.63 | 8.74 | 9.29 | 10.09 | 9.83 | 9.72 | 9.56 | 9.29 |
| 8 | 8.13 | 8.62 | 9.02 | 9.42 | 9.70 | 9.88 | 9.98 | 10.12 | 10.75 | 11.69 | 11.44 | 11.33 | 11.17 | 10.89 |
| 9 | 8.90 | 9.47 | 10.05 | 10.56 | 10.93 | 11.18 | 11.32 | 11.50 | 12.23 | 13.29 | 13.03 | 12.90 | 12.72 | 12.40 |
| 10 | 9.59 | 10.31 | 11.03 | 11.66 | 12.13 | 12.46 | 12.66 | 12.89 | 13.71 | 14.91 | 14.63 | 14.50 | 14.29 | 13.93 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 14.630 |
| SC2 | 0 | 8 | 10.115 |
| SC3 | -18 | 7 | 8.369 |
| SC4 | -25 | 6 | 6.837 |
| SC5 | -34 | 6 | 6.425 |
| A | 2407 mm |
|---|---|
| B | 523 mm |
| C | 445 mm |
| F | 345 mm |
| E1 | 428 mm |
| E2 | 410 mm |
| E | 2085 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 2407 mm |
|---|---|
| Width | 523 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.