EB-445AC6-B01 C
22.50 kW
Defrost: Electric
Product code: EB-440AC4-B01 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 13,366 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 76.7 m² |
| Inner volume | 13.6 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 112 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EB-440AC4-B01 C | None |
|---|---|
| EB-440AC4-B01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 9.33 | 9.51 | 9.68 | 9.82 | 9.87 | 9.84 | 9.76 | 9.87 | 10.48 | 11.33 | 11.04 | 10.94 | 10.81 | 10.57 |
| 5 | 11.65 | 12.05 | 12.44 | 12.78 | 13.01 | 13.13 | 13.17 | 13.30 | 14.12 | 15.28 | 14.86 | 14.71 | 14.49 | 14.16 |
| 6 | 13.78 | 14.40 | 14.91 | 15.44 | 15.79 | 16.00 | 16.10 | 16.31 | 17.33 | 18.82 | 18.42 | 18.26 | 18.03 | 17.65 |
| 7 | 15.67 | 16.57 | 17.40 | 18.13 | 18.62 | 18.93 | 19.07 | 19.32 | 20.54 | 22.31 | 21.83 | 21.64 | 21.34 | 20.84 |
| 8 | 17.40 | 18.61 | 19.73 | 20.71 | 21.40 | 21.84 | 22.02 | 22.33 | 23.74 | 25.80 | 25.27 | 25.04 | 24.70 | 24.12 |
| 9 | 18.98 | 20.52 | 21.95 | 23.06 | 23.96 | 24.59 | 24.98 | 25.38 | 27.00 | 29.37 | 28.80 | 28.54 | 28.15 | 27.46 |
| 10 | ≈ 20.40 | 22.29 | 23.87 | 25.41 | 26.58 | 27.40 | 27.93 | 28.44 | 30.27 | 32.94 | 32.35 | 32.07 | 31.63 | 30.86 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 32.351 |
| SC2 | 0 | 8 | 22.333 |
| SC3 | -18 | 7 | 18.350 |
| SC4 | -25 | 6 | 14.913 |
| SC5 | -34 | 6 | 13.925 |
| A | 2967 mm |
|---|---|
| B | 650 mm |
| C | 617 mm |
| F | 445 mm |
| E1 | 668 mm |
| E2 | 650 mm |
| E | 2635 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 2967 mm |
|---|---|
| Width | 520 mm |
| Height | 617 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.