ED-DP-245AE4-B24 C
17.36 kW
Defrost: None
Product code: ED-DP-345AC7-B24 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 11,426 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 60.6 m² |
| Inner volume | 19.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 152 kg |
| Quantity | 3 |
|---|---|
| Diameter | 450 mm |
| Speed | 900 rpm |
| Power | 570 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 49.0 dB(A) |
|---|---|
| Sound power | 71.2 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-DP-345AC7-B24 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.04 | 6.96 | 6.91 | 6.88 | 6.82 | 6.74 | 6.64 | 6.69 | 7.08 | 7.64 | 7.42 | 7.33 | 7.22 | 7.05 |
| 5 | 9.14 | 9.17 | 9.22 | 9.26 | 9.24 | 9.16 | 9.05 | 9.08 | 9.61 | 10.36 | 10.04 | 9.93 | 9.78 | 9.55 |
| 6 | 11.24 | 11.42 | 11.60 | 11.73 | 11.79 | 11.76 | 11.66 | 11.69 | 12.37 | 13.34 | 12.91 | 12.75 | 12.53 | 12.18 |
| 7 | 13.18 | 13.57 | 13.93 | 14.25 | 14.41 | 14.45 | 14.39 | 14.43 | 15.28 | 16.51 | 16.00 | 15.80 | 15.51 | 15.04 |
| 8 | 14.86 | 15.43 | 15.97 | 16.46 | 16.79 | 16.94 | 17.03 | 17.20 | 18.25 | 19.76 | 19.20 | 18.97 | 18.62 | 18.06 |
| 9 | 16.41 | 17.20 | 17.86 | 18.52 | 18.97 | 19.25 | 19.41 | 19.61 | 20.83 | 22.61 | 22.11 | 21.89 | 21.57 | 21.02 |
| 10 | 17.85 | 18.80 | 19.74 | 20.57 | 21.16 | 21.56 | 21.78 | 22.05 | 23.42 | 25.43 | 24.90 | 24.66 | 24.29 | 23.65 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.896 |
| SC2 | 0 | 8 | 17.195 |
| SC3 | -18 | 7 | 14.329 |
| SC4 | -25 | 6 | 11.598 |
| SC5 | -34 | 6 | 11.290 |
| A | 2748 mm |
|---|---|
| B | 1050 mm |
| C | 435 mm |
| F | 1090 mm |
| G | 540 mm |
| E1 | 2435 mm |
| E2 | 818 mm |
| E3 | 800 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2748 mm |
|---|---|
| Width | 1050 mm |
| Height | 540 mm |
Our engineers answer with a selection for your conditions.