ED-150AG7-C21 C
15.18 kW
Defrost: None
Product code: ED-530AE7-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 6,377 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 59.6 m² |
| Inner volume | 20.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 123 kg |
| Quantity | 5 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 310 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 49.0 dB(A) |
|---|---|
| Sound power | 71.2 dB(A) |
| Energy class | A |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-530AE7-C21 C | None |
|---|---|
| ED-530AE7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.64 | 6.60 | 6.59 | 6.61 | 6.59 | 6.55 | 6.48 | 6.57 | 6.98 | 7.55 | 7.37 | 7.31 | 7.22 | 7.10 |
| 5 | 8.41 | 8.45 | 8.52 | 8.60 | 8.61 | 8.58 | 8.50 | 8.57 | 9.08 | 9.82 | 9.53 | 9.43 | 9.28 | 9.05 |
| 6 | 10.12 | 10.28 | 10.45 | 10.62 | 10.69 | 10.68 | 10.61 | 10.67 | 11.30 | 12.22 | 11.84 | 11.69 | 11.47 | 11.12 |
| 7 | 11.82 | 12.11 | 12.39 | 12.66 | 12.78 | 12.82 | 12.77 | 12.84 | 13.59 | 14.70 | 14.25 | 14.06 | 13.78 | 13.32 |
| 8 | 13.37 | 13.82 | 14.26 | 14.65 | 14.89 | 14.98 | 14.95 | 15.04 | 15.93 | 17.22 | 16.72 | 16.50 | 16.17 | 15.61 |
| 9 | 14.75 | 15.37 | 15.95 | 16.48 | 16.82 | 16.98 | 17.06 | 17.23 | 18.27 | 19.75 | 19.21 | 18.96 | 18.58 | 17.93 |
| 10 | 16.03 | 16.84 | 17.60 | 18.19 | 18.65 | 18.93 | 19.06 | 19.25 | 20.42 | 22.13 | 21.60 | 21.35 | 20.96 | 20.29 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 21.596 |
| SC2 | 0 | 8 | 15.043 |
| SC3 | -18 | 7 | 12.705 |
| SC4 | -25 | 6 | 10.453 |
| SC5 | -34 | 6 | 10.171 |
| A | 2848 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 2535 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2848 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |