ED-440AC7-C21 C
19.95 kW
Defrost: Electric
Product code: ED-630AE4-C21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 7,126 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 114.1 m² |
| Inner volume | 24.0 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 151 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 372 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 73.0 dB(A) |
| Energy class | A |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-630AE4-C21 C | None |
|---|---|
| ED-630AE4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 8.14 | 8.32 | 8.51 | 8.68 | 8.78 | 8.81 | 8.78 | 8.99 | 9.58 | 10.42 | 10.21 | 10.14 | 10.05 | 9.92 |
| 5 | 10.19 | 10.55 | 10.88 | 11.19 | 11.37 | 11.45 | 11.43 | 11.62 | 12.35 | 13.41 | 13.07 | 12.93 | 12.73 | 12.41 |
| 6 | 12.17 | 12.73 | 13.25 | 13.71 | 14.00 | 14.12 | 14.13 | 14.32 | 15.20 | 16.50 | 16.04 | 15.85 | 15.56 | 15.08 |
| 7 | 13.92 | 14.70 | 15.42 | 16.06 | 16.49 | 16.69 | 16.79 | 17.03 | 18.08 | 19.59 | 19.06 | 18.82 | 18.46 | 17.83 |
| 8 | 15.47 | 16.50 | 17.46 | 18.19 | 18.78 | 19.13 | 19.29 | 19.56 | 20.77 | 22.53 | 21.98 | 21.72 | 21.31 | 20.60 |
| 9 | 16.88 | 18.18 | 19.25 | 20.31 | 21.08 | 21.55 | 21.79 | 22.10 | 23.47 | 25.45 | 24.84 | 24.54 | 24.08 | 23.24 |
| 10 | ≈ 18.16 | 19.61 | 21.06 | 22.36 | 23.32 | 23.94 | 24.27 | 24.64 | 26.17 | 28.39 | 27.73 | 27.39 | 26.86 | 25.92 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 27.725 |
| SC2 | 0 | 8 | 19.561 |
| SC3 | -18 | 7 | 16.257 |
| SC4 | -25 | 6 | 13.254 |
| SC5 | -34 | 6 | 12.307 |
| A | 3348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 3035 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 3348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.