ED-630AC4-C25 C
15.81 kW
Defrost: None
Product code: ED-630AE7-C25 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,738 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 71.5 m² |
| Inner volume | 24.0 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 137 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-630AE7-C25 C | None |
|---|---|
| ED-630AE7-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.88 | 6.89 | 6.93 | 6.98 | 6.98 | 6.94 | 6.86 | 6.99 | 7.43 | 8.05 | 7.86 | 7.79 | 7.71 | 7.58 |
| 5 | 8.65 | 8.77 | 8.90 | 9.03 | 9.07 | 9.05 | 8.97 | 9.08 | 9.63 | 10.43 | 10.12 | 10.01 | 9.84 | 9.59 |
| 6 | 10.41 | 10.61 | 10.87 | 11.10 | 11.22 | 11.24 | 11.17 | 11.26 | 11.94 | 12.92 | 12.50 | 12.34 | 12.09 | 11.68 |
| 7 | 12.01 | 12.44 | 12.83 | 13.18 | 13.39 | 13.45 | 13.40 | 13.51 | 14.31 | 15.48 | 14.98 | 14.77 | 14.45 | 13.92 |
| 8 | 13.51 | 14.11 | 14.67 | 15.18 | 15.50 | 15.66 | 15.66 | 15.79 | 16.72 | 18.08 | 17.50 | 17.25 | 16.87 | 16.23 |
| 9 | 14.84 | 15.63 | 16.37 | 17.03 | 17.39 | 17.65 | 17.75 | 17.96 | 19.04 | 20.62 | 20.06 | 19.78 | 19.34 | 18.58 |
| 10 | 16.07 | 17.08 | 18.01 | 18.72 | 19.29 | 19.64 | 19.80 | 20.05 | 21.26 | 23.03 | 22.44 | 22.15 | 21.70 | 20.91 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 22.436 |
| SC2 | 0 | 8 | 15.786 |
| SC3 | -18 | 7 | 13.281 |
| SC4 | -25 | 6 | 10.867 |
| SC5 | -34 | 6 | 10.471 |
| A | 3348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 3035 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 3348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.