ED-630AC4-C25 C
15.81 kW
Defrost: None
Product code: ED-630AE7-C25 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 6,738 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 71.5 m² |
| Inner volume | 24.0 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 137 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-630AE7-C25 C | None |
|---|---|
| ED-630AE7-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.23 | 6.24 | 6.29 | 6.34 | 6.36 | 6.34 | 6.30 | 6.45 | 6.87 | 7.47 | 7.32 | 7.28 | 7.22 | 7.14 |
| 5 | 8.02 | 8.13 | 8.25 | 8.37 | 8.43 | 8.42 | 8.37 | 8.50 | 9.03 | 9.80 | 9.54 | 9.45 | 9.32 | 9.13 |
| 6 | 9.74 | 9.98 | 10.22 | 10.44 | 10.55 | 10.59 | 10.54 | 10.66 | 11.31 | 12.26 | 11.90 | 11.76 | 11.54 | 11.19 |
| 7 | 11.44 | 11.83 | 12.19 | 12.52 | 12.70 | 12.79 | 12.76 | 12.89 | 13.66 | 14.80 | 14.35 | 14.16 | 13.87 | 13.40 |
| 8 | 12.98 | 13.55 | 14.08 | 14.56 | 14.86 | 15.00 | 15.00 | 15.16 | 16.06 | 17.38 | 16.87 | 16.64 | 16.29 | 15.69 |
| 9 | 14.37 | 15.11 | 15.80 | 16.43 | 16.84 | 17.05 | 17.15 | 17.38 | 18.44 | 19.97 | 19.40 | 19.14 | 18.73 | 18.02 |
| 10 | 15.63 | 16.58 | 17.46 | 18.15 | 18.69 | 19.04 | 19.20 | 19.46 | 20.65 | 22.38 | 21.83 | 21.56 | 21.13 | 20.40 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 21.828 |
| SC2 | 0 | 8 | 15.155 |
| SC3 | -18 | 7 | 12.591 |
| SC4 | -25 | 6 | 10.215 |
| SC5 | -34 | 6 | 9.804 |
| A | 3348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 3035 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 3348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.