EK-K-s-663BE10-B08 C
100.45 kW
Defrost: Electric
Product code: EK-K-b-663BE10-B29 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 89,222 m³/h |
|---|---|
| External surface | 329.6 m² |
| Inner volume | 141.3 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 794 kg |
| Quantity | 6 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 11,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 76.0 dB(A) |
|---|---|
| Sound power | 100.0 dB(A) |
| Energy class | E |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| EK-K-b-663BE10-B29 C | None |
|---|---|
| EK-K-b-663BE10-B29 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | ≈ 44.36 | ≈ 42.67 | ≈ 41.56 | ≈ 40.84 | ≈ 40.12 | ≈ 39.42 | ≈ 38.77 | ≈ 38.85 | ≈ 41.01 | ≈ 44.17 | ≈ 42.91 | ≈ 42.46 | ≈ 41.82 | ≈ 40.89 |
| 5 | ≈ 53.23 | ≈ 51.61 | ≈ 50.51 | ≈ 55.27 | ≈ 54.30 | ≈ 53.27 | 52.23 | ≈ 52.23 | ≈ 55.21 | ≈ 59.40 | ≈ 57.55 | ≈ 56.87 | ≈ 55.90 | ≈ 54.45 |
| 6 | ≈ 67.11 | ≈ 65.65 | 64.58 | ≈ 70.99 | ≈ 69.94 | ≈ 68.69 | 67.31 | ≈ 67.11 | ≈ 70.85 | ≈ 76.14 | ≈ 73.50 | ≈ 72.57 | ≈ 71.26 | ≈ 69.32 |
| 7 | ≈ 80.87 | ≈ 79.88 | ≈ 79.27 | ≈ 87.61 | ≈ 86.59 | ≈ 85.27 | 83.68 | ≈ 83.30 | ≈ 87.91 | ≈ 94.41 | ≈ 90.91 | ≈ 89.65 | ≈ 87.85 | ≈ 85.15 |
| 8 | ≈ 94.32 | ≈ 94.07 | ≈ 94.07 | ≈ 104.61 | ≈ 103.94 | ≈ 102.70 | 100.98 | 100.45 | ≈ 105.98 | ≈ 113.87 | 109.51 | 107.89 | 105.54 | 101.91 |
| 9 | ≈ 119.16 | ≈ 120.00 | ≈ 120.62 | ≈ 121.49 | ≈ 121.35 | ≈ 120.41 | 118.83 | 118.25 | 124.78 | 134.19 | 129.07 | 127.08 | 124.21 | 119.64 |
| 10 | ≈ 131.92 | ≈ 133.93 | ≈ 136.11 | ≈ 138.30 | ≈ 138.95 | ≈ 138.44 | 137.08 | 136.55 | 144.15 | 155.14 | 149.47 | 147.19 | 143.85 | 138.46 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | ≈ 44.36 | ≈ 42.68 | ≈ 41.58 | ≈ 40.86 | ≈ 40.14 | ≈ 39.43 | ≈ 38.77 | ≈ 39.07 | ≈ 41.25 | ≈ 44.44 | ≈ 43.19 | ≈ 42.74 | ≈ 42.11 | ≈ 41.18 |
| 5 | ≈ 53.24 | ≈ 51.62 | ≈ 50.53 | ≈ 55.30 | ≈ 54.31 | ≈ 53.28 | 52.23 | ≈ 52.47 | ≈ 55.55 | ≈ 59.81 | ≈ 57.99 | ≈ 57.31 | ≈ 56.34 | ≈ 54.90 |
| 6 | ≈ 67.12 | ≈ 65.67 | 64.61 | ≈ 71.03 | ≈ 69.95 | ≈ 68.69 | 67.31 | ≈ 67.25 | ≈ 71.08 | ≈ 76.42 | ≈ 73.77 | ≈ 72.87 | ≈ 71.61 | ≈ 69.75 |
| 7 | ≈ 80.89 | ≈ 79.91 | ≈ 79.32 | ≈ 87.66 | ≈ 86.61 | ≈ 85.27 | 83.67 | ≈ 83.33 | ≈ 87.99 | ≈ 94.51 | ≈ 90.94 | ≈ 89.67 | ≈ 87.87 | ≈ 85.17 |
| 8 | ≈ 94.33 | ≈ 94.11 | ≈ 94.13 | ≈ 104.67 | ≈ 103.96 | ≈ 102.70 | 100.97 | 100.46 | ≈ 105.99 | ≈ 113.88 | 109.50 | 107.88 | 105.53 | 101.90 |
| 9 | ≈ 119.19 | ≈ 120.07 | ≈ 120.71 | ≈ 121.57 | ≈ 121.38 | ≈ 120.42 | 118.82 | 118.25 | 124.77 | 134.19 | 129.06 | 127.07 | 124.19 | 119.61 |
| 10 | ≈ 131.94 | ≈ 134.00 | ≈ 136.21 | ≈ 138.39 | ≈ 138.99 | ≈ 138.45 | 137.07 | 136.54 | 144.14 | 155.13 | 149.46 | 147.17 | 143.82 | 138.41 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 149.473 | 149.462 |
| SC2 | 0 | 8 | 100.451 | 100.458 |
| SC3 | -18 | 7 | 87.277 | 87.315 |
| SC4 | -25 | 6 | 64.577 | 64.614 |
| SC5 | -34 | 6 | 66.880 | 66.893 |
| A | 3460 mm |
|---|---|
| B | 1050 mm |
| C | 1935 mm |
| F | 990 mm |
| G | 3035 mm |
| E | 2050 mm |
| G1 | 1035 mm |
| G2 | 1000 mm |
| D IN | 2 x Ø42 |
| D OUT | 2 x Ø66,7 |
| Length | 3460 mm |
|---|---|
| Width | 1050 mm |
| Height | 2050 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.