EK-T-163BG10-B08 C
20.68 kW
Defrost: None
Product code: EK-T-250AE10-B10 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 14,987 m³/h |
|---|---|
| External surface | 78.1 m² |
| Inner volume | 32.9 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 211 kg |
| Quantity | 2 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,360 rpm |
| Power | 1,380 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.3 dB(A) |
| Energy class | D |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø54 |
| EK-T-250AE10-B10 C | None |
|---|---|
| EK-T-250AE10-B10 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 8.99 | 8.68 | 8.49 | 8.39 | 8.27 | 8.16 | 8.06 | 8.10 | 8.57 | 9.25 | 9.00 | 8.92 | 8.79 | 8.61 |
| 5 | 10.64 | 10.34 | 10.16 | 11.16 | 11.01 | 10.86 | 10.69 | 10.70 | 11.32 | 12.20 | 11.85 | 11.72 | 11.55 | 11.29 |
| 6 | 13.25 | 12.99 | 12.83 | 14.15 | 13.99 | 13.80 | 13.59 | 13.55 | 14.32 | 15.42 | 14.92 | 14.74 | 14.49 | 14.12 |
| 7 | 15.91 | 15.71 | 15.60 | 17.27 | 17.13 | 16.93 | 16.69 | 16.61 | 17.54 | 18.88 | 18.24 | 18.00 | 17.66 | 17.14 |
| 8 | 18.50 | 18.41 | 18.40 | 20.48 | 20.39 | 20.20 | 19.94 | 19.84 | 20.95 | 22.55 | 21.76 | 21.46 | 21.03 | 20.36 |
| 9 | 23.33 | 23.42 | 23.56 | 23.72 | 23.70 | 23.56 | 23.32 | 23.20 | 24.49 | 26.37 | 25.46 | 25.10 | 24.58 | 23.74 |
| 10 | 26.00 | 26.31 | 26.64 | 26.90 | 27.00 | 26.92 | 26.72 | 26.62 | 28.12 | 30.29 | 29.27 | 28.86 | 28.26 | 27.28 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 7.99 | 7.72 | 7.57 | 7.49 | 7.41 | 7.33 | 7.25 | 7.32 | 7.77 | 8.40 | 8.20 | 8.13 | 8.02 | 7.87 |
| 5 | 9.39 | 9.13 | 8.97 | 9.87 | 9.76 | 9.64 | 9.51 | 9.55 | 10.12 | 10.92 | 10.63 | 10.53 | 10.38 | 10.17 |
| 6 | 11.66 | 11.40 | 11.25 | 12.42 | 12.29 | 12.14 | 11.97 | 11.97 | 12.66 | 13.65 | 13.23 | 13.08 | 12.87 | 12.56 |
| 7 | 13.99 | 13.74 | 13.62 | 15.08 | 14.96 | 14.79 | 14.59 | 14.55 | 15.37 | 16.56 | 16.02 | 15.82 | 15.53 | 15.09 |
| 8 | 16.27 | 16.11 | 16.05 | 17.81 | 17.72 | 17.55 | 17.33 | 17.27 | 18.24 | 19.64 | 18.97 | 18.72 | 18.35 | 17.77 |
| 9 | 20.56 | 20.50 | 20.53 | 20.61 | 20.56 | 20.40 | 20.17 | 20.09 | 21.21 | 22.85 | 22.06 | 21.75 | 21.30 | 20.58 |
| 10 | 22.97 | 23.07 | 23.22 | 23.41 | 23.41 | 23.29 | 23.08 | 22.99 | 24.28 | 26.15 | 25.26 | 24.90 | 24.37 | 23.51 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 29.270 | 25.263 |
| SC2 | 0 | 8 | 19.841 | 17.266 |
| SC3 | -18 | 7 | 17.219 | 15.036 |
| SC4 | -25 | 6 | 12.825 | 11.254 |
| SC5 | -34 | 6 | 13.208 | 11.619 |
| A | 2060 mm |
|---|---|
| B | 1050 mm |
| C | 935 mm |
| F | 840 mm |
| G | 1635 mm |
| E | 1050 mm |
| G1 | 835 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø54 |
| Length | 2060 mm |
|---|---|
| Width | 1050 mm |
| Height | 1050 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.