EA-G-480GD4-A01 C
126.98 kW
Defrost: None
Product code: EA-G-563FG4-A19 C
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Air flow | 52,246 m³/h |
|---|---|
| Air throw | 30 m |
| External surface | 835.3 m² |
| Inner volume | 179.7 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 628 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,330 rpm |
| Power | 6,250 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 66.0 dB(A) |
|---|---|
| Sound power | 90.0 dB(A) |
| Energy class | E |
| Inlet | 4" |
|---|---|
| Outlet | 4" |
| EA-G-563FG4-A19 C | None |
|---|
ΔT (air inlet − fluid inlet) must be within 6–12 K (fluid outlet = inlet + 3 K); air inlet -25…10 °C. Points below the fluid's freezing point are not rated.
ETHYLENE GLYCOL 30% -10 → -7 °C, air inlet 0 °C (ΔT 10 K)
ETHYLENE GLYCOL 30%; rows: ΔT = air inlet − fluid inlet [K], outlet = inlet + 3 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 27.21 | ≈ 27.06 | ≈ 27.18 | ≈ 47.67 |
| 8 | not rated | not rated | not rated | not rated | ≈ 45.21 | ≈ 82.61 | ≈ 91.95 | ≈ 101.53 |
| 10 | not rated | not rated | not rated | not rated | ≈ 118.68 | 127.17 | 136.38 | 149.33 |
| 12 | not rated | not rated | not rated | not rated | not rated | 166.18 | 178.58 | 194.42 |
| ΔT [K] \ air [°C] | -25 | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
|---|---|---|---|---|---|---|---|---|
| 6 | not rated | not rated | not rated | not rated | 25.46 | 24.86 | ≈ 24.95 | ≈ 24.86 |
| 8 | not rated | not rated | not rated | not rated | ≈ 41.81 | ≈ 39.18 | ≈ 74.89 | ≈ 84.71 |
| 10 | not rated | not rated | not rated | not rated | ≈ 93.79 | 104.52 | 113.31 | 124.21 |
| 12 | not rated | not rated | not rated | not rated | not rated | 137.32 | 148.27 | 161.32 |
Nominal conditions: ethylene glycol 30 % −10 → −7 °C, air inlet 0 °C, relative humidity 85 %
| Fan connection | Cooling capacity [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 127.170 | 39.93 | 79.0 |
| Low speed (Y) | 104.520 | 32.77 | 55.7 |
| A | 5415 mm |
|---|---|
| B | 1100 mm |
| C | 1190 mm |
| F | 1060 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 5035 mm |
| D IN | 4" |
| D OUT | 4" |
| Length | 5415 mm |
|---|---|
| Width | 1100 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.