Dry cooler BE-2x891EB1-B04T C

Dry cooler BE-2x891EB1-B04T C
Illustrative photo

Producer: Karyer · Line: BE (Dry)

Product code: BE-2x891EB1-B04T C

Heat rejection i
1367.47 kW
Air flow
431,939 m³/h
Fans
16 × ⌀910 mm

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Model nomenclature

How to read the code of this model.

  • A
    Series: BE — BE = V-type dry cooler.
  • C
    Fan rows (optional "Nx"): 2 — Catalogue: "Fan Row no." (number before x/X).
  • D
    Number of fans per row: 8 — Digit 1-9; total fans = fan rows x this digit.
  • E
    Fan diameter: 91 — Ø910 mm
  • G
    Coil tube rows (2nd dimensional letter): B — 3 tube rows
  • H
    Fin spacing: 1 — 2.1 mm
  • I
    Generation code: B — generation B
  • J
    Fan data (fan motor code): 04 — three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
  • K
    Delivery version (optional): T — T: truck delivery version

Data

Coil
Air flow 431,939 m³/h
External surface 3,816.9 m²
Inner volume 782.8 dm³
Fin materialAluminium
Net weight 4,847 kg
Fans
Quantity 16
Diameter 910 mm
Speed 840 rpm
Power 44,800 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 6
Acoustic
Sound pressure 70.0 dB(A)
Sound power 103.0 dB(A)
Energy class E
Connections
Inlet 5"
Outlet 5"
Defrost
BE-2x891EB1-B04T C None

Performance

Outlet 35 °C

Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.

WATER 40 → 35 °C, air inlet 25 °C

Heat rejection · High speed (Δ)
1367.474 kW Fluid flow 237.35 m³/h Pressure drop 85.2 kPa above the recommended pressure drop
Heat rejection · Low speed (Y)
1087.191 kW Fluid flow 188.68 m³/h Pressure drop 56.6 kPa

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)

WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.

High speed (Δ)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 798.15 not rated not rated not rated not rated not rated
40 1367.47 799.85 not rated not rated not rated not rated
45 1924.09 1365.58 801.26 not rated not rated not rated
50 2476.57 1918.87 1363.88 802.69 not rated not rated
55 3027.03 2468.11 1914.27 1362.81 804.45 not rated
60 3576.47 3015.42 2460.70 1910.93 1362.78 806.65

Low speed (Y)

Heat rejection [kW]: Air inlet × fluid inlet (range 5 K)
Fluid inlet [°C] \ air [°C] 253035404550
35 640.16 not rated not rated not rated not rated not rated
40 1087.19 641.42 not rated not rated not rated not rated
45 1523.23 1085.48 642.57 not rated not rated not rated
50 1955.53 1518.85 1084.20 643.87 not rated not rated
55 2386.23 1948.57 1515.19 1083.56 645.42 not rated
60 2815.95 2376.72 1942.83 1512.80 1083.83 647.48

Nominal rating

Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %

Fan connection Heat rejection [kW] Fluid flow [m³/h] Pressure drop [kPa]
High speed (Δ) 1367.474 237.35 85.2
Low speed (Y) 1087.191 188.68 56.6

Dimensions

Dimension drawing of BE-2x891EB1-B04T C
Dimension drawing
Dimensions as drawn
A 2880 mm
B 2400 mm
C 10050 mm
F 2330 mm
G 10650 mm
E1 1250 mm
E2 2400 mm
H 10300 mm
D IN 5"
D OUT 5"
Overall [mm]
Length 10650 mm
Width 2400 mm
Height 2880 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.