EA-430AC6-C01 C
9.19 kW
Defrost: Electric
Product code: EA-163EC10-C06 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 9,289 m³/h |
|---|---|
| Air throw | 22 m |
| External surface | 32.5 m² |
| Inner volume | 13.2 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 100 kg |
| Quantity | 1 |
|---|---|
| Diameter | 630 mm |
| Speed | 890 rpm |
| Power | 600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 52.0 dB(A) |
|---|---|
| Sound power | 73.8 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EA-163EC10-C06 C | None |
|---|---|
| EA-163EC10-C06 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.76 | 3.78 | 3.80 | 3.82 | 3.80 | 3.76 | 3.71 | 3.73 | 3.94 | 4.24 | 4.11 | 4.06 | 3.99 | 3.88 |
| 5 | 4.80 | 4.90 | 4.99 | 5.06 | 5.08 | 5.05 | 5.01 | 5.02 | 5.32 | 5.73 | 5.56 | 5.49 | 5.40 | 5.26 |
| 6 | 5.75 | 5.97 | 6.16 | 6.29 | 6.37 | 6.39 | 6.36 | 6.39 | 6.77 | 7.30 | 7.08 | 7.00 | 6.88 | 6.68 |
| 7 | 6.62 | 6.93 | 7.24 | 7.50 | 7.66 | 7.74 | 7.75 | 7.80 | 8.27 | 8.94 | 8.69 | 8.59 | 8.44 | 8.19 |
| 8 | 7.33 | 7.79 | 8.20 | 8.56 | 8.81 | 8.97 | 9.06 | 9.17 | 9.74 | 10.57 | 10.34 | 10.22 | 10.05 | 9.77 |
| 9 | 7.99 | 8.58 | 9.12 | 9.59 | 9.92 | 10.15 | 10.28 | 10.41 | 11.07 | 12.03 | 11.78 | 11.67 | 11.51 | 11.24 |
| 10 | ≈ 8.60 | 9.32 | 9.99 | 10.58 | 11.01 | 11.30 | 11.49 | 11.66 | 12.40 | 13.48 | 13.22 | 13.11 | 12.93 | 12.62 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.34 | 3.33 | 3.33 | 3.33 | 3.32 | 3.29 | 3.25 | 3.28 | 3.49 | 3.76 | 3.65 | 3.62 | 3.56 | 3.48 |
| 5 | 4.26 | 4.31 | 4.36 | 4.39 | 4.39 | 4.37 | 4.33 | 4.35 | 4.62 | 4.98 | 4.84 | 4.79 | 4.71 | 4.60 |
| 6 | 5.13 | 5.26 | 5.38 | 5.48 | 5.52 | 5.52 | 5.48 | 5.50 | 5.82 | 6.28 | 6.09 | 6.02 | 5.91 | 5.75 |
| 7 | 5.94 | 6.18 | 6.39 | 6.53 | 6.62 | 6.66 | 6.65 | 6.68 | 7.07 | 7.65 | 7.42 | 7.33 | 7.20 | 6.99 |
| 8 | 6.69 | 7.00 | 7.31 | 7.57 | 7.73 | 7.82 | 7.85 | 7.89 | 8.36 | 9.05 | 8.80 | 8.70 | 8.55 | 8.29 |
| 9 | 7.31 | 7.75 | 8.15 | 8.50 | 8.74 | 8.89 | 8.98 | 9.07 | 9.64 | 10.46 | 10.21 | 10.09 | 9.92 | 9.63 |
| 10 | 7.90 | 8.45 | 8.95 | 9.40 | 9.71 | 9.91 | 10.04 | 10.16 | 10.79 | 11.72 | 11.48 | 11.37 | 11.21 | 10.93 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 13.222 | 11.478 |
| SC2 | 0 | 8 | 9.165 | 7.892 |
| SC3 | -18 | 7 | 7.573 | 6.573 |
| SC4 | -25 | 6 | 6.161 | 5.383 |
| SC5 | -34 | 6 | 5.803 | 5.168 |
| A | 1215 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E | 835 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 1215 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.