EB-330BC4-B05 C
7.35 kW
Defrost: None
Product code: EB-235AC7-B01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,413 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 19.8 m² |
| Inner volume | 5.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 51 kg |
| Quantity | 2 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 330 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 51.0 dB(A) |
|---|---|
| Sound power | 73.0 dB(A) |
| Energy class | C |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø28 |
| EB-235AC7-B01 C | None |
|---|---|
| EB-235AC7-B01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.00 | 2.99 | 2.98 | 2.98 | 2.96 | 2.92 | 2.88 | 2.89 | 3.06 | 3.30 | 3.20 | 3.17 | 3.11 | 3.04 |
| 5 | 3.88 | 3.92 | 3.97 | 4.01 | 4.01 | 3.99 | 3.95 | 3.96 | 4.19 | 4.52 | 4.38 | 4.33 | 4.26 | 4.16 |
| 6 | 4.73 | 4.85 | 4.96 | 5.06 | 5.11 | 5.12 | 5.09 | 5.11 | 5.41 | 5.84 | 5.66 | 5.60 | 5.50 | 5.35 |
| 7 | 5.46 | 5.65 | 5.83 | 6.00 | 6.11 | 6.18 | 6.21 | 6.27 | 6.66 | 7.23 | 7.03 | 6.96 | 6.84 | 6.65 |
| 8 | 6.18 | 6.44 | 6.69 | 6.90 | 7.05 | 7.16 | 7.21 | 7.29 | 7.74 | 8.41 | 8.23 | 8.15 | 8.04 | 7.85 |
| 9 | 6.82 | 7.18 | 7.51 | 7.81 | 8.01 | 8.14 | 8.23 | 8.32 | 8.84 | 9.60 | 9.41 | 9.32 | 9.19 | 8.98 |
| 10 | 7.42 | 7.88 | 8.30 | 8.67 | 8.94 | 9.13 | 9.25 | 9.36 | 9.95 | 10.81 | 10.59 | 10.49 | 10.35 | 10.11 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 10.586 |
| SC2 | 0 | 8 | 7.289 |
| SC3 | -18 | 7 | 6.046 |
| SC4 | -25 | 6 | 4.958 |
| SC5 | -34 | 6 | 4.760 |
| A | 1557 mm |
|---|---|
| B | 520 mm |
| C | 553 mm |
| F | 345 mm |
| E1 | 618 mm |
| E | 1235 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø28 |
| Length | 1557 mm |
|---|---|
| Width | 520 mm |
| Height | 553 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.