ED-335AE4-C21 C
16.44 kW
Defrost: None
Product code: ED-530AE4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 5,940 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 95.1 m² |
| Inner volume | 20.1 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 129 kg |
| Quantity | 5 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 310 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 50.0 dB(A) |
|---|---|
| Sound power | 72.0 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-530AE4-C21 C | None |
|---|---|
| ED-530AE4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.80 | 6.82 | 6.88 | 6.96 | 6.99 | 6.99 | 6.95 | 7.12 | 7.59 | 8.25 | 8.09 | 8.04 | 7.98 | 7.88 |
| 5 | 8.66 | 8.78 | 8.91 | 9.05 | 9.12 | 9.13 | 9.08 | 9.22 | 9.79 | 10.63 | 10.36 | 10.26 | 10.12 | 9.89 |
| 6 | 10.51 | 10.70 | 10.95 | 11.18 | 11.30 | 11.34 | 11.29 | 11.41 | 12.10 | 13.12 | 12.74 | 12.59 | 12.36 | 11.99 |
| 7 | 12.22 | 12.61 | 12.99 | 13.32 | 13.52 | 13.59 | 13.55 | 13.67 | 14.48 | 15.68 | 15.21 | 15.02 | 14.72 | 14.22 |
| 8 | 13.80 | 14.36 | 14.89 | 15.38 | 15.69 | 15.85 | 15.84 | 15.96 | 16.91 | 18.27 | 17.74 | 17.50 | 17.13 | 16.51 |
| 9 | 15.22 | 15.98 | 16.68 | 17.30 | 17.66 | 17.89 | 17.97 | 18.15 | 19.25 | 20.84 | 20.29 | 20.02 | 19.59 | 18.85 |
| 10 | 16.54 | 17.51 | 18.31 | 19.10 | 19.63 | 19.95 | 20.08 | 20.28 | 21.51 | 23.28 | 22.69 | 22.40 | 21.95 | 21.16 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 22.685 |
| SC2 | 0 | 8 | 15.960 |
| SC3 | -18 | 7 | 13.419 |
| SC4 | -25 | 6 | 10.945 |
| SC5 | -34 | 6 | 10.572 |
| A | 2848 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 2535 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2848 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.