BE-2x380AD5-B01T C
466.00 kW
Defrost: None
Product code: BE-t-591GB1-B04 C
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Air flow | 138,519 m³/h |
|---|---|
| External surface | 1,057.6 m² |
| Inner volume | 136.7 dm³ |
| Fin material | Aluminium |
| Net weight | 1,318 kg |
| Quantity | 5 |
|---|---|
| Diameter | 910 mm |
| Speed | 840 rpm |
| Power | 14,000 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 65.0 dB(A) |
|---|---|
| Sound power | 97.0 dB(A) |
| Energy class | E |
| Inlet | 3" |
|---|---|
| Outlet | 3" |
| BE-t-591GB1-B04 C | None |
|---|
Fluid inlet 35–60 °C (outlet = inlet − 5 K, at least 5 K above the air inlet); air inlet 25…50 °C.
WATER 40 → 35 °C, air inlet 25 °C
WATER; rows: fluid inlet [°C], outlet = inlet − 5 K; columns: air inlet temperature. The highlighted cell is the nominal point. "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 262.65 | not rated | not rated | not rated | not rated | not rated |
| 40 | 464.96 | 264.69 | not rated | not rated | not rated | not rated |
| 45 | 660.74 | 464.93 | 266.40 | not rated | not rated | not rated |
| 50 | 854.34 | 659.07 | 464.91 | 267.88 | not rated | not rated |
| 55 | 1047.04 | 851.14 | 657.64 | 465.00 | 269.31 | not rated |
| 60 | 1239.15 | 1042.36 | 848.39 | 656.50 | 465.37 | 270.81 |
| Fluid inlet [°C] \ air [°C] | 25 | 30 | 35 | 40 | 45 | 50 |
|---|---|---|---|---|---|---|
| 35 | 210.91 | not rated | not rated | not rated | not rated | not rated |
| 40 | 370.14 | 212.57 | not rated | not rated | not rated | not rated |
| 45 | 523.25 | 369.96 | 213.94 | not rated | not rated | not rated |
| 50 | 674.48 | 521.68 | 369.75 | 215.13 | not rated | not rated |
| 55 | 824.82 | 671.67 | 520.37 | 369.74 | 216.30 | not rated |
| 60 | 974.66 | 820.81 | 669.27 | 519.42 | 370.01 | 217.55 |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
| Fan connection | Heat rejection [kW] | Fluid flow [m³/h] | Pressure drop [kPa] |
|---|---|---|---|
| High speed (Δ) | 464.958 | 80.69 | 26.5 |
| Low speed (Y) | 370.135 | 64.24 | 17.5 |
| A | 1958 mm |
|---|---|
| B | 1210 mm |
| C | 6460 mm |
| F | 1050 mm |
| G | 7060 mm |
| E1 | 1230 mm |
| E2 | 1200 mm |
| D IN | 3" |
| D OUT | 3" |
| Length | 7060 mm |
|---|---|
| Width | 1210 mm |
| Height | 1958 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.