- Catalogue
- Dry coolers
- BE (Dry)
BE (Dry)
- Refrigerants
- ETHYLENE GLYCOL 30%, PROPYLENE GLYCOL 30%, WATER
- Capacity
- 69.30–1727.54 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 10 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series BE = BE = V-type dry cooler.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| BE-491BC5-B04 C | 336.79 kW | 4 × ⌀910 | 111,178 |
Variants (1)
|
| BE-680BB5-B01 C | 337.60 kW | 6 × ⌀800 | 129,301 |
Variants (1)
|
| BE-t-2x280HB1-B01C C | 338.04 kW | 4 × ⌀800 | 86,619 |
Variants (1) |
| BE-t-391HB1-B04 C | 338.18 kW | 3 × ⌀910 | 87,651 |
Variants (1)
|
| BE-2x291AC1-C04C C | 338.92 kW | 4 × ⌀910 | 102,028 |
Variants (1) |
| BE-t-2x291GB1-C04C C | 339.08 kW | 4 × ⌀910 | 104,443 |
Variants (1) |
| BE-580BC5-B01 C | 339.29 kW | 5 × ⌀800 | 105,380 |
Variants (1)
|
| BE-t-2x291GB5-B04T C | 340.89 kW | 4 × ⌀910 | 110,393 |
Variants (1) |
| BE-2x280DD5-B01T C | 342.13 kW | 4 × ⌀800 | 87,123 |
Variants (1) |
| BE-491AB1-B04 C | 342.78 kW | 4 × ⌀910 | 112,614 |
Variants (1)
|
| BE-391DD1-B04 C | 342.98 kW | 3 × ⌀910 | 85,951 |
Variants (1)
|
| BE-2x380BB1-B01C C | 343.53 kW | 6 × ⌀800 | 123,163 |
Variants (1) |
| BE-480FB5-B01 C | 343.76 kW | 4 × ⌀800 | 90,155 |
Variants (1)
|
| BE-2x280CB1-B01T C | 344.39 kW | 4 × ⌀800 | 89,975 |
Variants (1) |
| BE-480AD1-B01 C | 344.57 kW | 4 × ⌀800 | 82,400 |
Variants (1)
|
| BE-2x291AC5-B04T C | 344.60 kW | 4 × ⌀910 | 108,577 |
Variants (1) |
| BE-391FB1-B04 C | 344.85 kW | 3 × ⌀910 | 89,502 |
Variants (1)
|
| BE-2x280DD1-B01C C | 345.04 kW | 4 × ⌀800 | 84,829 |
Variants (1) |
| BE-2x280CC5-B01C C | 345.85 kW | 4 × ⌀800 | 88,682 |
Variants (1) |
| BE-580EB5-B01 C | 346.98 kW | 5 × ⌀800 | 106,883 |
Variants (1)
|
| BE-391CC5-B04 C | 348.79 kW | 3 × ⌀910 | 89,661 |
Variants (1)
|
| BE-t-480GC1-B01 C | 349.23 kW | 4 × ⌀800 | 81,442 |
Variants (1)
|
| BE-2x380AB5-B01C C | 350.63 kW | 6 × ⌀800 | 125,799 |
Variants (1) |
| BE-2x291BC1-B04T C | 352.78 kW | 4 × ⌀910 | 108,320 |
Variants (1) |
| BE-t-491GB5-B04 C | 353.94 kW | 4 × ⌀910 | 111,904 |
Variants (1)
|
| BE-480CB1-B01 C | 354.13 kW | 4 × ⌀800 | 90,408 |
Variants (1)
|
| BE-t-391HC5-B04 C | 354.68 kW | 3 × ⌀910 | 86,664 |
Variants (1)
|
| BE-2x291DC5-C04C C | 354.96 kW | 4 × ⌀910 | 113,180 |
Variants (1) |
| BE-t-2x280HB1-B01T C | 356.12 kW | 4 × ⌀800 | 87,982 |
Variants (1) |
| BE-t-2x291GC5-C04C C | 356.47 kW | 4 × ⌀910 | 101,446 |
Variants (1) |
| BE-t-2x280HC5-B01C C | 357.94 kW | 4 × ⌀800 | 85,590 |
Variants (1) |
| BE-t-580GB5-B01 C | 358.85 kW | 5 × ⌀800 | 106,076 |
Variants (1)
|
| BE-391FC5-B04 C | 358.96 kW | 3 × ⌀910 | 88,823 |
Variants (1)
|
| BE-2x280CC5-B01T C | 359.09 kW | 4 × ⌀800 | 89,502 |
Variants (1) |
| BE-580AB1-B01 C | 360.10 kW | 5 × ⌀800 | 107,759 |
Variants (1)
|
| BE-2x291DB1-B04T C | 360.47 kW | 4 × ⌀910 | 117,316 |
Variants (1) |
| BE-2x280DD1-B01T C | 360.92 kW | 4 × ⌀800 | 86,569 |
Variants (1) |
| BE-491AC5-B04 C | 361.94 kW | 4 × ⌀910 | 110,786 |
Variants (1)
|
| BE-2X380BC5-B01C C | 363.37 kW | 6 × ⌀800 | 120,414 |
Variants (1) |
| BE-591BB5-B04 C | 363.85 kW | 5 × ⌀910 | 142,513 |
Variants (1)
|
| BE-2x291CB5-C04C C | 365.00 kW | 4 × ⌀910 | 118,390 |
Variants (1) |
| BE-491BC1-B04 C | 365.22 kW | 4 × ⌀910 | 110,032 |
Variants (1)
|
| BE-480FB1-B01 C | 365.45 kW | 4 × ⌀800 | 89,900 |
Variants (1)
|
| BE-2x280CC1-B01C C | 365.81 kW | 4 × ⌀800 | 88,273 |
Variants (1) |
| BE-580BC1-B01 C | 365.81 kW | 5 × ⌀800 | 104,273 |
Variants (1)
|
| BE-480CC5-B01 C | 368.54 kW | 4 × ⌀800 | 90,014 |
Variants (1)
|
| BE-391CC1-B04 C | 369.32 kW | 3 × ⌀910 | 89,282 |
Variants (1)
|
| BE-2x380BB1-B01T C | 369.55 kW | 6 × ⌀800 | 126,843 |
Variants (1) |
| BE-580AC5-B01 C | 370.46 kW | 5 × ⌀800 | 106,403 |
Variants (1)
|
| BE-2x280CD5-B01C C | 370.65 kW | 4 × ⌀800 | 87,793 |
Variants (1) |
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
Downloads
- BE-491BC5-B04 C — product datasheet (PDF)
- BE-680BB5-B01 C — product datasheet (PDF)
- BE-t-2x280HB1-B01C C — product datasheet (PDF)
- BE-t-391HB1-B04 C — product datasheet (PDF)
- BE-2x291AC1-C04C C — product datasheet (PDF)
- BE-t-2x291GB1-C04C C — product datasheet (PDF)
- BE-580BC5-B01 C — product datasheet (PDF)
- BE-t-2x291GB5-B04T C — product datasheet (PDF)
- BE-2x280DD5-B01T C — product datasheet (PDF)
- BE-491AB1-B04 C — product datasheet (PDF)
- BE-391DD1-B04 C — product datasheet (PDF)
- BE-2x380BB1-B01C C — product datasheet (PDF)
- BE-480FB5-B01 C — product datasheet (PDF)
- BE-2x280CB1-B01T C — product datasheet (PDF)
- BE-480AD1-B01 C — product datasheet (PDF)
- BE-2x291AC5-B04T C — product datasheet (PDF)
- BE-391FB1-B04 C — product datasheet (PDF)
- BE-2x280DD1-B01C C — product datasheet (PDF)
- BE-2x280CC5-B01C C — product datasheet (PDF)
- BE-580EB5-B01 C — product datasheet (PDF)
- BE-391CC5-B04 C — product datasheet (PDF)
- BE-t-480GC1-B01 C — product datasheet (PDF)
- BE-2x380AB5-B01C C — product datasheet (PDF)
- BE-2x291BC1-B04T C — product datasheet (PDF)
- BE-t-491GB5-B04 C — product datasheet (PDF)
- BE-480CB1-B01 C — product datasheet (PDF)
- BE-t-391HC5-B04 C — product datasheet (PDF)
- BE-2x291DC5-C04C C — product datasheet (PDF)
- BE-t-2x280HB1-B01T C — product datasheet (PDF)
- BE-t-2x291GC5-C04C C — product datasheet (PDF)
- BE-t-2x280HC5-B01C C — product datasheet (PDF)
- BE-t-580GB5-B01 C — product datasheet (PDF)
- BE-391FC5-B04 C — product datasheet (PDF)
- BE-2x280CC5-B01T C — product datasheet (PDF)
- BE-580AB1-B01 C — product datasheet (PDF)
- BE-2x291DB1-B04T C — product datasheet (PDF)
- BE-2x280DD1-B01T C — product datasheet (PDF)
- BE-491AC5-B04 C — product datasheet (PDF)
- BE-2X380BC5-B01C C — product datasheet (PDF)
- BE-591BB5-B04 C — product datasheet (PDF)
- BE-2x291CB5-C04C C — product datasheet (PDF)
- BE-491BC1-B04 C — product datasheet (PDF)
- BE-480FB1-B01 C — product datasheet (PDF)
- BE-2x280CC1-B01C C — product datasheet (PDF)
- BE-580BC1-B01 C — product datasheet (PDF)
- BE-480CC5-B01 C — product datasheet (PDF)
- BE-391CC1-B04 C — product datasheet (PDF)
- BE-2x380BB1-B01T C — product datasheet (PDF)
- BE-580AC5-B01 C — product datasheet (PDF)
- BE-2x280CD5-B01C C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.