ED-530AE4-C25 C
14.71 kW
Defrost: Electric
Product code: ED-150AE4-C21 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 6,648 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 68.1 m² |
| Inner volume | 14.1 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 91 kg |
| Quantity | 1 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,300 rpm |
| Power | 680 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 78.1 dB(A) |
| Energy class | D |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-150AE4-C21 C | None |
|---|---|
| ED-150AE4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.70 | 5.60 | 5.56 | 5.55 | 5.53 | 5.50 | 5.46 | 5.58 | 5.94 | 6.45 | 6.33 | 6.28 | 6.22 | 6.13 |
| 5 | 7.58 | 7.50 | 7.48 | 7.48 | 7.45 | 7.39 | 7.32 | 7.41 | 7.87 | 8.52 | 8.32 | 8.25 | 8.16 | 8.04 |
| 6 | 9.49 | 9.49 | 9.52 | 9.56 | 9.54 | 9.47 | 9.37 | 9.43 | 9.99 | 10.80 | 10.48 | 10.37 | 10.22 | 9.99 |
| 7 | 11.42 | 11.52 | 11.64 | 11.74 | 11.76 | 11.70 | 11.57 | 11.61 | 12.28 | 13.26 | 12.83 | 12.67 | 12.44 | 12.08 |
| 8 | 13.23 | 13.49 | 13.74 | 13.96 | 14.05 | 14.01 | 13.89 | 13.91 | 14.71 | 15.87 | 15.34 | 15.13 | 14.83 | 14.34 |
| 9 | 14.81 | 15.23 | 15.63 | 16.00 | 16.22 | 16.30 | 16.27 | 16.30 | 17.21 | 18.57 | 17.97 | 17.71 | 17.34 | 16.73 |
| 10 | 16.29 | 16.88 | 17.43 | 17.86 | 18.16 | 18.31 | 18.34 | 18.47 | 19.57 | 21.18 | 20.61 | 20.37 | 19.93 | 19.20 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 20.614 |
| SC2 | 0 | 8 | 13.910 |
| SC3 | -18 | 7 | 11.754 |
| SC4 | -25 | 6 | 9.519 |
| SC5 | -34 | 6 | 9.503 |
| A | 1368 mm |
|---|---|
| B | 1350 mm |
| C | 405 mm |
| F | 1135 mm |
| G | 506 mm |
| E1 | 1035 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 1368 mm |
|---|---|
| Width | 1210 mm |
| Height | 506 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.