ED-450AG7-C21 C
59.14 kW
Defrost: None
Product code: ED-450AE4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
| Air flow | 26,557 m³/h |
|---|---|
| Air throw | 21 m |
| External surface | 273.2 m² |
| Inner volume | 58.3 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 297 kg |
| Quantity | 4 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,300 rpm |
| Power | 2,720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 84.1 dB(A) |
| Energy class | D |
| Inlet | Ø42 |
|---|---|
| Outlet | Ø66,7 |
| ED-450AE4-C21 C | None |
|---|---|
| ED-450AE4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 24.47 | 25.04 | 25.56 | 26.03 | 26.24 | 26.25 | 26.11 | 26.66 | 28.39 | 30.81 | 30.19 | 29.98 | 29.70 | 29.28 |
| 5 | 31.29 | 32.51 | 33.61 | 34.54 | 34.99 | 35.18 | 35.09 | 35.62 | 37.84 | 41.04 | 39.96 | 39.58 | 39.02 | 38.19 |
| 6 | 37.22 | 39.11 | 40.85 | 42.38 | 43.21 | 43.83 | 44.08 | 44.77 | 47.60 | 51.73 | 50.37 | 49.82 | 49.02 | 47.71 |
| 7 | 42.39 | 45.08 | 47.21 | 49.36 | 50.85 | 51.77 | 52.22 | 53.00 | 56.33 | 61.24 | 59.83 | 59.25 | 58.36 | 56.84 |
| 8 | 47.10 | 50.27 | 53.48 | 56.33 | 58.36 | 59.65 | 60.35 | 61.29 | 65.14 | 70.79 | 69.22 | 68.51 | 67.43 | 65.56 |
| 9 | ≈ 51.03 | 55.36 | 59.42 | 63.05 | 65.71 | 67.46 | 68.47 | 69.61 | 74.01 | 80.42 | 78.71 | 77.90 | 76.64 | 74.43 |
| 10 | ≈ 54.82 | 60.05 | 65.01 | 69.49 | 72.81 | 75.13 | 76.52 | 77.92 | 82.88 | 90.10 | 88.29 | 87.38 | 85.96 | 83.42 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 88.285 |
| SC2 | 0 | 8 | 61.289 |
| SC3 | -18 | 7 | 50.031 |
| SC4 | -25 | 6 | 40.850 |
| SC5 | -34 | 6 | 37.664 |
| A | 4368 mm |
|---|---|
| B | 1350 mm |
| C | 405 mm |
| F | 1135 mm |
| G | 506 mm |
| E1 | 4035 mm |
| E2 | 1018 mm |
| E3 | 1000 mm |
| D IN | 1 x Ø42 |
| D OUT | 1 x Ø66,7 |
| Length | 4368 mm |
|---|---|
| Width | 1210 mm |
| Height | 506 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.